Home page Product catalogue  Surgical equipment  Infusion systems  Infusion pump Alaris Asena CC
Print version
Infusion pump Alaris Asena CC
Manufacturer: Cardinal Health Alaris

 ALARIS ASENA CC Syringe Pump

The Alaris® CC Syringe Pump with its variable pressure monitoring system helps reduce some of the risks associated with undetected occlusions, as the user can select the appropriate pressure levels to suit the needs of the individual patient. This may be particularly important for critical infusions, when drugs with a short half-life are being infused, in the adult Critical Care or in the Neonatal Unit.

Intensivists have the highest expectations of their infusion pumps. Safety, ease of use, and practicality are just some of the most basic requirements. The Alaris® CC Syringe Pump from Cardinal Health, delivers exclusive capabilities for significant bedside advantages. Among these are drug and drug dosing capabilities, in-line pressure sensor technology, and real time pressure monitoring. Improving the early detection of occlusions, by reducing time to alarm, can help prevent sub-therapeutic medication and the risk of post occlusion bolus.

Шприцевой насос

Key Features:

  • Infusion Rates: 0.1-1200ml/h; in steps of 0.1ml/h
  • Medical Device Interface (MDI)
  • Pole Clamp
  • Real Time Clock
  • Syringe sizes: 5, 10, 20, 30 & 50ml
  • Event log
  • Event log events: 1,500
  • Automatic Bolus Reduction
  • Rate Lock Facillity
  • Auto-night Mode
  • Pressure display
  • Drug names
  • Volume to be infused (VTBI)
  • Volume infused (VI)
  • Pressure alarm level
  • Drive Linearity: +/- 1%
  • Volumetric Mean Accuracy: +/- 2%
  • Communications: Bi-directional IrDa
  • RS 232 port: Optional
  • Battery Life: 4 hours at 5ml/h; when fully charged
  • Battery run time: Charge 2 1/2 hours with fast; charge to 90% of charge
  • Class: Class 1 Type CF; Electrical Safety Test